59Service Manual – CS7010™ 04 - Control System
Device Output Dependencies
When troubleshooting machine devices, it is helpful to know under what conditions that device is normally
permitted to operate. The table below lists these dependencies for each device in the machine.
Output Dependencies
Output Dependencies Comments
PowerModule
Contactor K2
• KeySwitchInput(KSI)ishigh
• CommunicatingwithMainMachineController
(Certain faults can turn this
output off)
PowerModule
Contactor K3
• KeySwitchInput(KSI)ishigh
• CommunicatingwithMainMachineController
(Certain faults can turn this
output off)
Main Relay K1 •
KeySwitchInput(KSI)ishigh
• No main relay fault.
Dust Guard Pump and
Solenoid Valve
•
DustguardenabledinCongurationMenu
• Sweepsystemactive
• Positive throttle % value from Wheel Drive
Controller
• No main broom, side broom or DustGuard
system faults
• Hopperinterlockswitchclosed
• Not turned off by operator
Thisbasicallytracksthesweep
system. Anything that inhibits
sweepwillinhibitdustguard.
Dust Fan Motor M2 • Hopperdown
• Seatswitchclosed
• E-Stop closed
• BatteryInterlockclosed
• No critical faults
• Hoppertempswitchopen(Ifinstalledand
congured)
• Positive throttle % value from Wheel Drive
Controller
• No main broom system faults
• NotinLowVoltageCut-out
• Not shut off by operator pressing side broom
button
Turnsonautomaticallywhen
sweepisstarted.
Ifinneutral,thedustfanturns
onautomaticallywhenthe
hopper is raised
Throttle 1 • No throttle output fault
Throttle 2 • No throttle output fault
StartOutput • No start output fault
IgnitionOutput • No ignition output fault
GlowPlugOutput • Noglowplugoutputfault
Hydraulic Pump Motor
(up)
• Not in Panel Test
• NotinOutputTest
• No hopper output fault
• DumpDoorswitchSW13closed
Ifthedumpdoorisopen,it
willbeclosedrst,unlessthe
hopper is already partially up.
Hydraulic Pump Motor
(down)
• Not in Panel Test
•
NotinOutputTest
• No hopper output fault
• HopperInterlockSwitchopen
Clutch High Pressure
Pump
• "Menu" not active
• No high pressure pump fault