234Service Manual – CS7010™ 34 - Scrub System
Scrub Motor
1. Remove the Scrub Deck described on page
232.
2. Disconnect the electrical connector from the
Scrub Motor Assembly.
3. Remove the Scrub Brush from the Brush Plate
Assembly.
4. Remove the Socket Head Screw from the
gearbox shaft and carefully remove the Brush
Plate Assembly.
5. Remove the four Hex Head Metric Screws,
then lift the Scrub Motor Assembly and Motor
Spacer off of the Arm Weldment (shown) or
deck weldment.
6. Reassemble the Scrub Motor Assembly
following the above steps in reverse order.
Note: Make sure the Key is installed
correctly before you reinstall the
Brush Plate Assembly onto the
scrub motor shaft.
Scrub
Brush
5/16-18 X 1.25
Socket Head Screw
Scrub
Motor
Assembly
Electrical
Connector
Motor
Spacer
Brush Plate
Assembly
Key
Hex Head Metric
Screw (4)
Swingarm
Weldment