290Service Manual – CS7010™ 50 - Dust Control/DustGuard™ Systems
Adjust the DustGuard Spray Nozzles
The Spray Nozzles should be approximately 10 to
20 degrees from vertical as shown in order to spray
the water evenly top to bottom in front of the side
brooms. (Note that the hopper has been raised
slightly in the adjacent photo.) The spray pattern
should wet the oor across the whole width of the
side broom. If the spray pattern is not correct:
1. Carefully rotate the Plastic Nozzle Adapter with
a 7/8” Wrench to orient the Spray Nozzle.
2. After you rotate the Plastic Nozzle Adapter,
make sure the Brass Nozzle Adapter is holding
Plastic Nozzle Adapter securely in the Nozzle
Bracket. Tighten the Brass Nozzle Adapter to
the Plastic Nozzle Adapter as necessary.
Troubleshooting
Problem Cause Correction
The DustGuard
system does not
operate.
The DustGuard system is not
installedintheconguration
menu.
MakesuretheDustGuardsystemisinstalledinthe
congurationmenu.
Inadequatewater
owtotheDustGuard
nozzles
Inadequatewaterlevelin
upper hopper
Checkthewaterlevel.
Thewaterstrainerscreenis
plugged.
Clean the strainer screen.
Thewaterhoses/nozzlesare
plugged.
Checkandcleanthewaterhoses/nozzlesas
necessary.
Thewatersolenoidvalveis
plugged or not functioning
correctly.
• Checkforvoltageatthesolenoidvalve.Ifthereis
voltage replace the solenoid valve.
• Ifthereisnovoltageatthesolenoid,checkthe
wiringandcircuitbreakersupstreamofthesolenoid.
The DustGuard pump is not
operating correctly.
• Checkforvoltageatthepump.Ifthereisvoltageat
the pump, replace the pump.
• Ifthereisnovoltageatthepump,checkthewiring
andcircuitbreakersupstreamofthepump.
The dust control
motorwillnotrun.
CloggedFilterswitch 1. Cleanthelter.
2. Checkthelterswitch.Theswitchshouldbeopen
withnovacuuminthehopperReplacethedust
controllterswitchifnecessary.
Failed motor. Use service test mode to test the motor.
Theshakermotorwill
not run.
Failed motor. Use service test mode to test the motor.
Spray