239Service Manual – CS7010™ 34 - Scrub System
Specications
Component Specications
Scrub Brush Motors (all) 35 VDC, 1 HP, 2750 RPM, 26 Amp
Scrub Brush Motor - Center
CurrentDraw(shop
measurements)
Average - 19 Amps Max. - 37 Amps
Scrub Brush Motor - Left
CurrentDraw(shop
measurements)
Average - 17 Amps Max. - 23 Amps
Scrub Brush Motor - Right
CurrentDraw(shop
measurements)
Average - 17 Amps Max. - 26 Amps
Deck Actuator Motor
InputVoltage-34-40VDC
Dynamic Load - 500 lbs. max.
Static Load - 1000 lbs. max.
Restraining Torque - 100 in.-lbs. min.
CurrentDraw
9 Amps max at rated dynamic load
2-5 Amps Typical
EndofStroke-Balldetentclutchwithaloadratingbetween600and1000lbs.;
willratchetatendofstroke
ThermalProtection-Automaticresettingthermalbreakerenclosedinmotor
housing.
Wiring Polarity:
•
Toextendactuator,connectredleadtopositiveandyellowleadtonegative.
• Toretractactuator,connectyellowleadtopositiveandredleadtonegative.
Retract Limit Switch
(Proximity Sensor)
AirGap@Make-.250in.(typical)
AirGap@Break-.313in.(typical)
Contact resistance (initial) - 150 milliohms max.
Special Tools
A spring puller is recommended to remove the Extension Springs from the
WeldmentArmswhenremovingtheSideSqueegeeAssemblies.Thereare
severaltypesofspringpullers-atypicalexampleisshownhere.