253Service Manual – CS7010™ 40 - Recovery System
Clean the Debris Basket
1. Unhook the latch, open the recovery
tank cover and lift the debris basket out
of the recovery tank.
2. Rinse any accumulated material from
the debris basket, then reinstall it in the
recovery tank.
3. Close the recovery tank cover and secure
the latch.
Troubleshooting
Problem Cause Correction
An individual vacuum
motorwillnotrun.
No voltage to the
vacuum motor.
Checkthewiringandconnectionstothevacuummotorand
repair as necessary.
The motor is not
operating correctly.
Ifthereisvoltagetothevacuummotor,replacethemotor.
Poorwaterpick-up. There is a vacuum
leakbetweenthe
squeegeeweldment
andtherecoverytank.
• Makesurethesqueegeehoseisinstalledcorrectlyinthe
recoverytankandonthesqueegeeweldment.
• Checkthesqueegeehoseforblockage,damageorcracks
and repair/replace as necessary.
The squeegee is
plugged.
•
Checkthesqueegeeandclean/repairasnecessary.
The squeegee
blade(s)is/areworn
out.
• Flipthesqueegeeblade(s)aroundtopositionanewblade
surfaceontheoor.
• Replace the squeegee blade(s).
Recovery
Tank Cover
Debris
Basket
Latch