286Service Manual – CS7010™ 50 - Dust Control/DustGuard™ Systems
Dust Control Filter Switch
The optional Dust Control Filter Switch is mounted
above the Filter Shaker Assembly on the Upper Hopper.
The Dust Control Filter Switch will close and generate a
warning if the hopper vacuum gets too high, indicating a
plugged Dust Control Filter. Note that the Dust Control
Filter Switch is factory-set to close at 2” of water, 0.147”
Hg or 0.072 psi.
If the dust control lter switch is not installed in the
hopper, there will be a Threaded Plug installed in the
switch hole.
Dust Control
Filter Switch
Threaded
Plug