270Service Manual – CS7010™ 42 - Sweep System, Main
Specications
Component Specications
Main Broom Motor
RPM - 3400
Voltage - 36 VDC
Amperage - 26 Amps
Main Broom Actuator
Dynamic Load - 400 lbs. maximum
Static Load - 1000 lbs. maximum
Restraining Torque - Actuator is internally restrained
InputVoltage-30to40VDC
Amperage - 4 Amps at rated dynamic load
OverloadProtection-Balldetentclutchwithloadratingbetween450and700lbs.
ThermalProtection-Automaticresettingthermalbreakerenclosedinmotor
housing.
Wiring Polarity:
•
Toextendactuator,connectredleadtopositiveandyellowleadtonegative.
• Toretractactuator,connectyellowleadtopositiveandredleadtonegative.