43Service Manual – CS7010™ 04 - Control System
Neutral Delay (s): This sets how long the brushes remain active
(in seconds) when the machine is stationary. The minimum is 1/2
second, the maximum is 5 seconds, and the increment is every 1/2
second.
Solution: This sets the mode for solution rate. The choices are
Proportional (based on travel speed) and Fixed (constant rate).
Solution In Rev: This sets whether solution will ow when the
machine is in reverse.
Shaker Time: This sets the length of time the shaker operates when activated.
Broom Up in Rev: This sets whether the main broom is raised
when the machine moves in reverse.
Squeegee Up Time: This sets the amount of time that the main
controller activates the actuator motor in the upward direction after
it sees a “reverse movement” signal.
Vac Off Delay (s): This sets the length of time (in seconds) that the
vacuum motor will continue to run after the squeegee is lifted (to
clear the hose of remaining water). The minimum is 10 seconds, the
maximum is 20 seconds, and the increment is every 1 second.
Enable RTF (Recovery Tank Full): This enables detection of a full recovery tank by monitoring a sudden
drop of the vacuum motor amperage.
Max Speed (%): This sets the maximum speed (percent of
maximum) the operator can propel the machine forward. The
minimum is 50%, the maximum is 100%, and the increment is every
10%.
Lock Speed Limit: This sets whether the operator can use the “set
max speed” feature.
Headlights: This sets whether the optional headlights are
automatically turned on at startup.
Steering Home Enable: This enables the steering home routine at machine initialization. When active, the
drive wheel will turn full-left and then to center to establish home and limit positions.
Backup Alarm: This sets when the backup alarm is active. The choices are Off, Reverse, Reverse/Forward,
Reverse/Forward/Hopper Up.
Options (8/16)
Neutral Delay
Back
Select
Solution
Solution in Rev
0.5
Proportional
No
Shaker Time 15
Options (12/16)
Broom Up in Rev
Back
Select
Sqg Up Time
Vac Off Delay
Yes
2.00
12
Enable RTF Yes
Options (13/16)
Max Speed (%)
Back
Select
Lock Speed Limit
Headlights
100
No
Manual
Backup Alarm Rev