Bravo-Brava
Electrical system
Fiat CODE
55.
The
key
memorization procedure
on an
unused system
is not
successful
if:
-
a key is
inserted
for 2
consecutive times;
-
the
same
key is
inserted
2 or
more times between
2
insertions
of a
MASTER
key;
-
a
period when
the key is at the
ignition
on
position
(+15)
lasts
for
more than
2
seconds;
-
a
period when
the key is at the
STOP position lasts more than
10
seconds.
On completion
of
memorization, ensure that all the keys supplied start the engine;
if
one
of
the keys does
not start
the
engine, repeat
the key
memorization procedure.
NOTE The memorization procedure
has
been described
for 3
keys (including
the
MASTER),
but
should be applied to
all
the keys supplied with the vehicle, plus any additional keys.
-
If
the procedure has
not
been carried
out
correctly,
the
memorization procedure should
be
repeated
very carefully.
-
If for any
reason
and at any
time during
the key
memorization procedure
you
notice that
you
have
made
a
mistake, move the key
to
the
on (+15)
position
for
over
2 s or to
the
off
(STOP) position
for
over 10 s, then start the key memorization procedure from
the
beginning.
>
KEY
CODE
WARNING
LIGHT
POSITIVE
RESULT
CODE
WARNING
LIGHT NEG.
RESULT
k
Master
<2s
0,7
s
0,7
s
<10s
Key1
<2s
0,7
s
0,7
s
<10s
Key
2
<2s
0,7
s
0,7
s
<10s
Master Master
<2s
0,7
s
0,7
s
>3s
0,7
s
ON
^-
1,6 Hz
0,7
s
50% d.c.
•4-2,5
S-*
P4A067L01
The diagram shows
how the
CODE warning light comes
on
depending
on the key
memorization.
Key memorization with UNUSED Fiat CODE control unit and USED electronic fuel injection control
unit
For the key memorization procedure with unused Fiat CODE control unit and used electronic fuel injec-
tion control unit, follow the instructions given
in the
"key memorization with unused system" described
above.
Copyright Fiat Auto