73
5-40. SYNCHRONIZER
Simultaneous 4K/HD
Dual HD
3D-LUT (FS1)
Item
Default
Setting
Description
Genlock
Source
GENLOCK
IN
GENLOCK IN
FS1
FS2
Free Run
Selects the reference signal (for both FS1 and
FS2).
GENLOCK IN: GENLOCK input signal
FS 1/2: Input signal selected for Synchronizer 1 or
Synchronizer 2.
Free Run: Internal reference signal.
Mode
Frame
Frame
Line
AVDL
Line(Min)
Selects the reference mode.
Use “Frame” if genlock input and video input
signals are not synchronized. When adjusting
video signals, the reference point (H: 0, V: 0) can
be offset under Timing settings. If the reference
point is changed, adjustable ranges are also
changed accordingly.
See the chart below for details on adjustable
ranges.
Frame: Aligns input video signals using frame
memory.
Line: Aligns input video signals using using 1H
memory.
AVDL: Aligns input video signals using both 1H
and frame memory.
Line (Min): Aligns input video signals using 1H
memory.
Signal Synchronization and Signal Timing Control
Bars in the figure below represent adjustable timing ranges for reference modes.
If timing difference of input signal exceeds the range, one frame delay may be added to the
signal or output image may be shifted vertically.
-6H -5H -4H -3H -2H -1H 0H
Frame adjust range:
-2.0H (for 4K/HD/SD Single Link signals)
(-2.0H or advanced signals, no frame delay.
Otherwise, a frame delay may occur.)
-4.0H (for 4K Dual/Quad Link signals)
AVDL adjust range:
-6.0H to -0.5H
(A frame delay may occur, if input signals
exceed the range)
Line adjust range:
-1.5H to -0.5H (Output mages may be shifted
vertically, if input signals exceed the range.)
Line(MIN) adjust range:
-(1H+700clk) to -700clk (Output mages may be shifted
vertically, if input signals exceed the range.)
Synchronizer output timing: Timing H:0, V:0
(The timing reference point can be offset. See next page.)