3/3
3. Mode
33040
33040
Processor Settings
$ SM Forced Replenishment Amount Setting (Initial value: See the table below.) (Input range: 0.0 to 999.9
mL)
This is the limit amount when carrying out forced replenishment.
When the forced replenishment amount reaches this value, each replenishment pump stops.
IMPORTANT
• Do not change it to any other value than the initial value of the forced replenishment amount.
$ Revolution Count
The number of pump revolution when each pump operates replenishment with the value input in Forced
Replenishment Amount Setting is shown.
3701 3703
Processing solution SM Forced Replenishment
Amount
Processing solution SM Forced Replenishment
Amount
CD-A 58.1 CD-A 55.3
CD-B 58.1 CD-B 55.3
CD-C 83.0 CD-C 79.0
BF-A 41.7 BF-A 41.7
BF-B 60.5 BF-B 60.5
STB 30.0 STB 30.0