Attention message: Processor
1/12
4. Troubleshooting
40500
40500
Attention messag e: Proc essor
No. 00500[N]
Add water to the Refilling Water Tank.
Attention message release
YES
Condition
Diagnosis
$ Symptoms due to connection failure of wiring/symptoms resulted from blowout of fuse
NOTE
• To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
00000 The refilling water tank level sensor turns off.
Failed part Manual No.
Refilling water tank level sensor
☞63290
Processor control PCB ☞66200
Processor I/O PCB 1 ☞66210
Processor power supply 2
☞67400
Symptoms due to the wiring connection failure Symptoms of fuse blowout
− ☞4203 ☞4252