EasyManua.ls Logo

Frontier LP7700 - No. 06177 Laser Unit Temperature Is out of Range

Frontier LP7700
904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Troubleshooting
46100
21/33
46100
Error message: Printer 2
No. 06177
Laser Unit temperature is out of range.
Error message release
NO
Condition
NOTE
The laser thermosensor is built into the laser unit.
You can check the temperature of laser unit in Input Check.
35210
Temperature of the laser unit heater, B laser heater and R laser heater is adjusted at the same time.
Check Point
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
00001 Laser temperature is controlled once between 15.0°C and 42.0°C for ten seconds or more (standby status) and
then the temperature exceeds 45.0°C (upper limit temperature) again.
00002 Laser temperature is controlled once between 15.0°C and 42.0°C for ten seconds or more (standby status) and
then the temperature falls under 15.0°C (lower limit temperature) again.
1 See 4302
If temperature of the laser unit thermosensor is not within the range from 15.0°C to 42.0°C
Failed part Manual No.
Laser control PCB 66010
Laser unit
63080
Laser unit heater 63080
Laser unit cooling fan 1 or 2 63050