Processor Standard Setting
1/2
3. Mode
33504
33504
Processor Set Up Mode[F]
!
!!
! Display
Bringing up the display
Maintenance: 2260 → Extension → Processor Settings → Processor Standard Setting → Processor Set Up Mode
!
!!
! Explanation
!
!!
! Initial Replenisher Operation (Auto Cleaning Pump)
• At the installation, you can exhaust the air remaining in the hose by operating PSR Replenisher Pump,P1 Auto Cleaning Valve
+ Replenisher Cartridge Cleaning Pump, P2 Auto Cleaning Valve + Replenisher Cartridge Cleaning Pump and PS Auto
Cleaning Valve + Replenisher Cartridge Cleaning Pump for a specified time.
To cancel Initial Replenisher Operation (Auto Cleaning Pump), press Cancel.
!
!!
! Mixing Replenisher
• There are two functions in Manual Operation: creating replenishment solution and the resetting the remaining amount of the
replenishment solution.
• If air in the auto cleaning pump is not exhausted during installation, the auto cleaning pump may be damaged. Be sure to perform
Processor Set Up Mode in the above order.
• If the air in the hose cannot be exhausted even though after performing Initial Replenisher Operation (Auto Cleaning Pump),
exhaust the air by operating the pump of hose that the air remains by Measure Auto Cleaning Water Output Amount via F:
Functions from Auto Cleaning Water Output Amount Setting, or Pump Output Amount Measurement via F: Functions from
Pump Output Amount Setting.
M5474-00
S4509-00-SM01
S4509-00-SM02
Distributed by: minilablaser.com