EasyManua.ls Logo

Frontier LP7700 - Refilling Water Amount Setting [N

Frontier LP7700
904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Processor Standard Setting
1/3
3. Mode
33510
33510
Refilling Water Amount Setting [N]
Description for each specification
In this section, the location of information varies depending on the specification. See below for the description for each specification.
For SM, see Refilling Water Amount Setting [SM].
!
!!
! Display
Bringing up the display
Maintenance: 2260ExtensionProcessor SettingsProcessor Standard SettingRefilling Water Amount Setting
!
!!
! Explanation
!
!!
! Process Specification
The process specification which has been registered in the machine specification is shown.
35800
!
!!
! Refilling Water Amount Setting (Initial value: See the table below.) (Input range: 0.0 to 999.9 ml)
The output amount of automatic refilling for each refilling water pump is set.
$ Refilling Water Amount Setting 1
When refilling water with Refilling Water Level off, set the refilling water amount after Refilling Water Level is set
to on. (For automatic refilling water during start up checks and normal processing.)
$ Refilling Water Amount Setting2
Set the refilling water amount with Refilling Water Level on. (For automatic refilling during start up checks.)
Refilling Water
Amount Setting 1
Refilling Water
Amount Setting 2
CD-W 186.0 79.5
BF-W 185.0 56.0
STB1-W 360.0 71.4
STB2-W 139.0 71.8
STB3-W 130.0 79.4
STB4-W 202.0 71.5
M5440-00
Distributed by: minilablaser.com

Table of Contents

Related product manuals