Processor Standard Setting
1/2
3. Mode
33540
33540
Refilling Water Amount Setting [J]
Bringing up the display
Maintenance: 2260ExtensionProcessor SettingsProcessor Standard SettingRefilling Water Amount Setting
!
!!
! Explanation
!
!!
! Environment Setting (Initial value: (1) 12-2 (2) 3-5 (3) 6-8 (4) 9-11 ) (Input range: 1 to 12)
A year can be divided into 4 environments and their periods can be set for the evaporation refill.
NOTE
If any of 12 months is not set, it cannot be registered even if Enter is clicked.
Example: (1) 1-6 (2) 8-12
In this case, it cannot be registered because July is missing.
• Clicking Environment Setting Cancel initializes the value.
!
!!
! Environment Correction Setting (Input range: 0 to 4)
The magnification of Evaporation Refill Amount can be set for each environment.
NOTE
The value can be set freely for No.4. (input range: 0.0 to 9.9)
!
!!
! Basic Evaporation Refill Amount (Input range: 0.0 to 99.9 ml)
The value for Evaporation Refill Amount can be set freely for both Working and Not Working.
No.
Magnification
Working Not working
00.0 1.0
10.6 0.6
21.0 1.0
31.4 1.4
4 Free setting Free setting
Magnification Condition
0.0 No refilling water
0.6 Humid condition
1.0 Standard condition
1.4 Dry condition
M5452-00