3. Mode
33590
2/2
33590
Processor Standard Setting
$ Returning Operating Time (after Paper Rear End Detected) (input range: 0.00 to 9.90 seconds)
Specify the time from when the dryer select sensor finishes the detection of the paper until the Dryer selection
solenoid 2 turns off.
Model Dryer selection solenoid 2 (default value) Returning Operating Time (after Paper
Rear End Detected) (default value)
LP7500 3701/3702 5.80 seconds 17.0 seconds
LP7600 3703 4.60 seconds 17.0 seconds
LP7700 3704 3.20 seconds 9.30 seconds
LP7900 3705 2.50 seconds 9.30 seconds