3. Mode
35952
35952
Self-diagnostic
The laser intensity is maximum when synchronous detection power is set to 100. Reducing the amount of this
value decreases laser intensity, and with 1 which is the smallest, the laser intensity is zero.
Therefore, the point at which the synchronous detection cannot be performed (asynchronous point) must
exist between 100 to 1%. Asynchronous point tends to become larger with less light intensity and smaller with
more light intensity.
For example, asynchronous point is at 100% for a system with little laser light and high occurrence frequency
of asynchronous detection, 70% for a system with low laser light and low occurrence frequency of
asynchronous detection, 20% for a system with appropriate laser light intensity.
3. Number of failed synchronous detection is detected with G laser synchronous detection power set to a
value between 61 and 100 before replacing parts
Confirm that there is no connection failure in wiring between the laser control PCB and the laser unit.
Confirm that there is no connection failure in wiring between the laser control PCB and the G-AOM driver.
4. Perform Laser Self-Diagnostic (Manual) again, and if there are no changes, replace the G-AOM driver.
5. If replacing the G-AOM drive changed nothing, replace the laser unit.