3. Mode
36010
2/3
36010
Printer Mechanical Adjustment
!
!!
! Test Operation for the Paper Stop Position Correction
The input correction value is invalidated and the paper is advanced to the arm unit 2.
!
!!
! Paper Stop Position Correction Test Operation Confirmation
The input correction value is validated and the paper is advanced to the arm unit 2.
!
!!
! Adjusting procedure
1. Execute Arm Unit 2 (Left) Receive Stop Position Correction Test Operation via F: Functions.
2. Open the printer top cover and check the condition of arm unit 2.
3. Input the correction value so that the distance between the upper end of paper guide in paper advance
unit 1 and front end of arm unit 2 becomes 55.3±0.5 mm.
NOTE
• Positive correction makes the arm unit move away from paper advance unit 1 and negative correction makes it move close.
4. After inputting the correction value, execute Arm Unit 2 (Left) Receive Stop Position Correction Test
Operation via F: Functions, then check that the value is 55.3±0.5 mm.
5. Correct the arm unit 2 (right) receive stop position in the same way.
6. Execute Test Operation for the Paper Stop Position Correction via F: Functions.
7. Open the printer top cover and check the condition of arm unit 2 and paper.
55.3±0.5 mm
Paper advance unit 1
Arm unit 2 (upper)
Upper paper guide
G068451
Distributed by: minilablaser.com