2. Replacement and adjustment of parts
25810
2/2
25810
Exposure advance unit
!
!!
! Adjusting the attaching position
1. The exposure advance unit has positioning pin(s). No position adjustment is needed in attaching the
exposure advance unit.
!
!!
! Adjustment after reattaching and setup
When the original exposure advance unit is reattached
• There is no need for adjustment.
When the new exposure advance unit is attached
1. Perform Paper Sensor Adjustment.
☞36000
2. Adjust the zigzagging of the exposure advance unit.
☞36080
3. Perform the exposure advance adjustment.
☞36080
4. Check the exposure center correction.
☞36070