EasyManuals Logo

Gemalto CINTERION BGS2T User Manual

Gemalto CINTERION BGS2T
554 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #192 background imageLoading...
Page #192 background image
BGS2T AT Command Set
8.8 AT^SMOND
BGS2T_ATC_V01.301 Page 192 of 554 1/31/12
c
Bit Error rate, with value 99 indicating "not known or not detectable"
0...7 as RXQUAL values RXQUAL0 to RXQUAL7 in 3GPP TS 45.008 [39] section
8.2.4
Notes
• To some extent, the cell monitoring commands AT^SMOND, AT^MONI, AT^MONP and AT^SMONC cover the
same parameters. The receiving level, for example, can be queried with all three commands. Yet the resulting
values may be slightly different, even though obtained over a time period of a few seconds. This is quite nor-
mal and nothing to worry about, as the cell information is permanently updated.
• During a connection, not all of the neighbour cell information can be decoded. The following restrictions apply:
- Information is updated only for neighbour cells that have already been visible at connection setup, and
continue to be included in the list of cells.
- New neighbour cells added to the list, for example after handover, cannot be displayed until the connection
is released.
Example
<BER>
(num)
at^smond
Execute command
^SMOND:262,01,3008,6060,32,100,66,,,0,,,0,
262,01,3008,DDD1,35,92,80,
262,01,3008,,31,96,83,
262,01,3008,BFBE,35,27,86,
262,01,3008,,32,98,88,
262,01,3008,BB44,32,90,89,
262,01,3008,8307,31,22,93,
2,23,99
Line breaks inserted for readability in print
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals