EasyManuals Logo

Gemalto CINTERION BGS2T User Manual

Gemalto CINTERION BGS2T
554 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #336 background imageLoading...
Page #336 background image
BGS2T AT Command Set
11.22 Using GPRS AT commands (Examples)
BGS2T_ATC_V01.301 Page 336 of 554 1/31/12
c
11.22 Using GPRS AT commands (Examples)
Examples
EXAMPLE 1
Defining and using a Context Definition ID (CID):
Every time a CID is used as a parameter for a GPRS command the CID has to be defined before by using
the AT+CGDCONT command. To get the parameter of a CID use the AT+CGDCONT read option. If the response
of 'AT+CGDCONT?' is OK only, there is no CID defined.
All parameters of the CID are initiated by NULL or not present values, and the CID itself is set to be undefined.
To define a CID use the AT+CGDCONT command with at least one CID parameter. At the moment the mobile
supports CID 1 and CID 2 by using the AT+CGDCONT command.
Define CID 1 and set the PDP type to IP, access point name and IP address are not set:
Define CID 2 and sets PDP type, APN and IP addr:
A following read command will respond:
Set the CID 1 to be undefined:
A following read command will respond:
AT+CGDCONT?
OK
There is no CID defined
AT+CGDCONT=1,"IP"
OK
AT+CGDCONT=2,"IP", "internet.t-d1.gprs", 111.222.123.234
OK
AT+CGDCONT?
+CGDCONT:1,"IP","","",0,0
+CGDCONT:2,"IP","internet.t-d1.gprs",111.222.123.234
OK
AT+CGDCONT=1
OK
AT+CGDCONT?
+CGDCONT:2,"IP","internet.t-d1.gprs",111.222.123.234
OK
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals