BGS2T AT Command Set
15.14 AT^SSTGI
BGS2T_ATC_V01.301 Page 440 of 554 1/31/12
c
15.14 AT^SSTGI SAT Get Information - Launch Browser (21)
This command shall be used after receiving the URC ^SSTN: 21.
If the SIM Application attempts to start an Internet Browser, it uses this response to inform the TE of the launch
parameters.
The sequence of events is as follows:
1. After the Remote-SAT notification 21 was issued the TE shall ask for the command parameters via
AT^SSTGI=21.
2. The ME shall ask the user for confirmation using the Alpha Identifier/Icon Identifier (user confirmation phase)
if present, when it receives a LAUNCH BROWSER command which requests to connect the existing browser
session to a new URL or to terminate a browser session.
3. If the user confirms to start the browser, AT^SSTR=21,0 shall be responded.
4. If the user denies to start the browser, AT^SSTR=21,34 shall be responded.
5. The SIM Application will end the proactive session.
6. The ME shall request content using the given URL. However, if no URL string is supplied a default URL shall
be used.
7. On response AT^SSTR=21,0 the browser session may still be active while a next proactive command is
issued. Therefore the end of the browser session shall be reported to the ME via browser termination event com-
mand asynchronously if determined by the event list.
For details please refer to AT^SSTR.
Syntax
Parameter Description
21 Proactive command ID, see Remote-SAT Command Types
This byte is RFU.
String for user confirmation stage
0...255 Used as bit field
bit 1 0: Icon is self explanatory and replaces text
Write Command
AT^SSTGI=21
Response(s)
^SSTGI: <cmdType>, <commandDetails>, <confirmationText>,
<confirmationIconQualifier>, <iconId>, <browserIdentity>, <url>, <bearerList>,
<fileRefList>, <gatewayIdentity>
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3 Last
- + + + + - -
<cmdType>
(num)
<commandDetails>
(num)
<confirmationText>
(str)
<confirmationIconQualifier>
(num)
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals