BGS2T AT Command Set
18.2 ATS3
BGS2T_ATC_V01.301 Page 516 of 554 1/31/12
c
18.2 ATS3 Command Line Termination
ATS3 determines the character recognized by the BGS2T to terminate an incoming command line. It is also gen-
erated for result codes and information text, along with character value set via ATS4.
Syntax
Parameter Description
Command line termination character.
It is not recommended to change this value.
000...13
(&F)
...127
Note
If changing this setting the new value has no effect for "^SHUTDOWN" URC.
Read Command
ATS3?
Response(s)
<n>
OK
Write Command
ATS3=<n>
Response(s)
OK
ERROR
PIN ASC0 MUX1 MUX2 MUX3 Last Reference(s)
- + + + + - - V.250
<n>
(num)(&W)(&V)