BGS2T AT Command Set
2.3 AT&W
BGS2T_ATC_V01.301 Page 37 of 554 1/31/12
c
2.3 AT&W Store AT Command Settings to User Defined Profile
AT&W stores the current AT command settings to a user defined profile in non-volatile memory of BGS2T. The
AT command settings will automatically be restored from the user defined profile during power-up or if ATZ is
used. AT&F restores AT command factory default settings. Hence, until first use of AT&W, ATZ works as AT&F.
A list of parameters stored to the user profile can be found at Section 19.5, AT Command Settings storable
with AT&W.
Syntax
Parameter Description
[0] User Profile Number
Exec Command
AT&W[<value>]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3 Last Reference(s)
- + + + + - - V.250
<value>
(num)