3.2 AT+CIND
BGS2T_ATC_V01.301 Page 66 of 554 1/31/12
c
3.2 AT+CIND Indicator control
The AT+CIND command controls the presentation of Indicator Event Reports related to various functions such
as signal quality, service availability, sound generation, indication of unread short messages, full SMS storage,
call in progress or roaming activities.
Use of AT+CIND has become outdated. Rather we recommend the more powerful AT^SIND command which is
easier to use and provides additional indicators. All indicators provided by AT+CIND can be handled with
AT^SIND as well.
AT+CIND supports two ways to get the values related to indicators:
One approach is to query the current status of each indicator by using the read command AT+CIND?. It
returns the status no matter whether the indicator has been registered with the write command
AT+CIND=[<mode>[,<mode>[,...]]].
The other way is an event-driven notification based on the "+CIEV" URCs. In this case, the ME will automat-
ically send a message to the application, whenever the value of an indicator changes. The application should
be designed to react adequately when receiving a URC.
The presentation of these URCs depends on two settings:
- The indicators must be registered with the write command AT+CIND=[<mode>[,<mode>[,...]]]. When the
ME is switched on all of them are in registered mode. Any indicator can be excluded if deregistered with
<mode>=0. To register or deregister an indicator the AT+CIND write command requires to type the value
<mode>=1 or 0 exactly at the position where the indicator is located in the list. This is not necessary with
AT^SIND which allows to specify indicators by name. See examples below.
- The presentation of the registered indicators must be enabled with AT+CMER.
Syntax
Parameter Description
Integer type value, which shall be in range of corresponding <indDescr>
Test Command
AT+CIND=?
Response(s)
+CIND: (<indDescr>, list of supported <indValue>s)[, (<indDescr>, list of supported <indValue>s)[,
...]]
OK
Read Command
AT+CIND?
Response(s)
+CIND: <indValue>[, <indValue>[, ...]]
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CIND=<mode>[, <mode>[, ...]]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3 Last Reference(s)
- + + + + - - 3GPP TS 27.007 [35]
<indValue>
(num)
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals