BGS2T AT Command Set
2. Configuration Commands
BGS2T_ATC_V01.301 Page 33 of 554 1/31/12
c
2. Configuration Commands
The AT Commands described in this chapter allow the external application to determine the BGS2T's behaviour
under various conditions.
2.1 AT&F Reset AT Command Settings to Factory Default Values
AT&F resets AT command settings to their factory default values.
Every ongoing or incoming call will be terminated.
For a list of affected parameters refer to Section 19.6, Factory Default Settings Restorable with
AT&F.
Syntax
Parameter Description
[0] Reset parameters in Section 19.6, Factory Default Settings Restor-
able with AT&F to their factory default values.
Exec Command
AT&F[<value>]
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3 Last Reference(s)
- + + + + - - V.250
<value>
(num)