BGS2T AT Command Set
8.18 AT^SPCL
BGS2T_ATC_V01.301 Page 208 of 554 1/31/12
c
Parameter Description
Two byte location area code in hexadecimal format (e.g. "3008" equals 12296 in decimal).
Two byte cell ID in hexadecimal format (e.g. "77D5" equals 30677 in decimal).
0 Not registered to a listed preferred cell. Normal cell selection applies.
1 Registered to a listed preferred cell.
Note
URC "^SPCL: 1" is only generated as long as the ME is registered to the home network and the current serv-
ing cell is recorded in the preferred cell list.
<LAC>
(str)
<cell>
(str)
<status>
(num)