BGS2T AT Command Set
10.2 AT^SICI
BGS2T_ATC_V01.301 Page 248 of 554 1/31/12
c
After closing the last service with AT^SISC:
at^sici?
Query once again the current status of the connec-
tion profile.
^SICI: 1,2,1,"10.10.0.161"
Parameter <numServices> has decreased.
OK
at^sici?
Query once again the current status of the connec-
tion profile.
^SICI: 1,2,1,"10.10.0.161"
The bearer is still open because of the inactivity time-
out "inactTO" of AT^SICS.
OK
at^sici?
Query again the current status.
^SICI: 1,0,0,"0.0.0.0"
The inactivity timeout "inactTO" of AT^SICS has
expired, therefore the bearer is closed now. Param-
eter <numServices> has decreased.
OK