Table 29: M40e or M160 Router Chassis Component Alarm
Conditions (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
YellowFor technical
support, open a
support case using
the Case Manager
link at
http://www.juniper.net
/support/ or call
1-888-314-JTAC
(within the United
States) or
1-408-745-9500
(outside the United
States).
The router boots from an
alternate boot device: the hard
disk. Typically, the router boots
from the flash drive. If you
configure your router to boot
from the hard disk, ignore this
alarm condition.
Alternative media
RedInsert a CIP into an
empty slot.
A CIP is missing.CIP
RedReplace the failed
craft interface.
The craft interface failed.Craft interface
YellowInstall the missing
fan tray.
One fan tray was removed from
the chassis.
Fan trays
RedInstall the missing
fan trays.
Two or more fan trays were
removed from the chassis.
RedReplace the fan tray.One fan in the chassis is not
spinning or is spinning below the
required speed.
YellowReplace the failed
FPC.
An FPC has an out-of-range or
invalid temperature reading.
FPC
RedReplace the failed
FPC.
An FPC microcode download
failed.
RedReplace the failed
FPC.
An FPC failed. If this occurs, the
FPC attempts to reboot. If the
MCS sees that an FPC is
rebooting too often, it shuts
down the FPC.
RedReplace the failed
FPC.
Too many hard errors in FPC
memory.
RedReplace the failed
FPC.
Too many soft errors in FPC
memory.
81Copyright © 2012, Juniper Networks, Inc.
Chapter 3: Method and Tools for Monitoring Router Components