Table 29: M40e or M160 Router Chassis Component Alarm
Conditions (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
YellowReformat the hard
disk and install a
bootable image. If
this fails, replace the
failed Routing
Engine.
Error in reading or writing hard
disk.
Routing Engine
YellowReformat the
CompactFlash card
and install a
bootable image. If
this fails, replace the
failed Routing
Engine.
Error in reading or writing
CompactFlash card.
YellowInstall a bootable
image on the default
master Routing
Engine. If this fails,
replace the failed
Routing Engine.
System booted from the default
backup Routing Engine. If you
manually switched mastership,
ignore this alarm condition.
YellowInstall a bootable
image on the
CompactFlash card.
If this fails, replace
the failed Routing
Engine.
System booted from hard disk.
RedReplace the failed
Routing Engine.
Compact flash is missing in the
boot list.
RedReplace the failed
Routing Engine.
Hard disk is missing in the boot
list.
RedReplace the failed
Routing Engine.
Routing Engine failed to boot.
YellowInsert a power supply
into the empty slot.
A power supply was removed
from the chassis.
Power supplies
RedReplace the failed
power supply.
A power supply failed.
83Copyright © 2012, Juniper Networks, Inc.
Chapter 3: Method and Tools for Monitoring Router Components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals