11-15
11-3 List of Display Items in Access Window
ACCESS WINDOW
- SV Series User’s Manual -
3. Parameter
Alarm
Parameter *2 Parameter *2
ALM_10 DevAlmLevel (CMD_PLS) ALM_10 DevAlmLevel (CMD_PLS)
ALM_11 DevWrnLevel (%) ALM_11 DevWrnLevel (%)
ALM_12 SpdLimAtSvon (min
-1
) ALM_12 SpdLimAtSvon (min
-1
)
Other
Parameter *2 Parameter *2
OTH_01 Brk-SvoffDel (x10ms)
○
OTH_01 Brk-SvoffDel (x10ms)
○
OTH_02 Brk OutSpd (min
-1
)
○
OTH_02 Brk OutSpd (min
-1
)
○
OTH_03 Brk WaitTime (x10ms)
○
OTH_03 Brk WaitTime (x10ms)
○
OTH_04 JOG Speed (min
-1
)
○
OTH_04 JOG Speed (min
-1
)
○
OTH_05 PTN Move
○
OTH_05 PTN Move
○
OTH_06 PTN Move Dis (CMD_PLS)
○
OTH_06 PTN Move Dis (CMD_PLS)
○
OTH_07 PTN Move Spd (min
-1
)
○
OTH_07 PTN Move Spd (min
-1
)
○
OTH_08 PTN AcDcTime (ms)
○
OTH_08 PTN AcDcTime (ms)
○
OTH_09 PTN WaitTime (ms)
○
OTH_09 PTN WaitTime (ms)
○
OTH_10 PTNMoveTimes (times)
○
OTH_10 PTNMoveTimes (times)
○
OTH_11 *3PH/1PH PWR
○
OTH_11 *3PH/1PH PWR
○
OTH_12 AW Contrast
○
OTH_12 AW Contrast
○
OTH_13 AW Language
○
OTH_13 AW Language
○
OTH_14 AW DisplayLv
○
OTH_14 AW DisplayLv
○
OTH_15 Analog monitor 1 OTH_15 Analog monitor 1
OTH_16 Analog monitor 2 OTH_16 Analog monitor 2
OTH_17 AMon1 Offset (x0.1V) OTH_17 AMon1 Offset (x0.1V)
OTH_18 AMon2 Offset (x0.1V) OTH_18 AMon2 Offset (x0.1V)
OTH_19 AMon Mag 1 (x0.01) OTH_19 AMon Mag 1 (x0.01)
OTH_20 AMon Mag 2 (x0.01) OTH_20 AMon Mag 2 (x0.01)
OTH_23 *MtrLessTest OTH_21 V-REF Filter (x0.01ms)
OTH_24 *MLessEnType OTH_22 T-REF Filter (x0.01ms)
OTH_25 *200V Power OTH_23 *MtrLessTest
OTH_26 *MainVolDrop OTH_24 *MLessEnType
OTH_27 TrqLmAtLowV (%) OTH_25 *200V Power
OTH_28 TrqLmRelTime (ms) OTH_26 *MainVolDrop
OTH_29 Pow HoldTime (ms) OTH_27 TrqLmAtLowV (%)
OTH_28 TrqLmRelTime (ms)
OTH_29 Pow HoldTime (ms)
IO
Parameter *2 Parameter *2
IO_37 *IN1 Assign
IO_43 *IN7 Assign
○
IO_01 *IN1 assignment
IO_11 *IN1 assignment
○
IO_44 *FSTOP Pol
○
IO_12 *FSTOP polarity
○
IO_45 *IN1 Pol
IO_51 *IN7 Pol
○
IO_13 *IN1 polarity
IO_23 *IN1 polarity
○
IO_24 *SVON AutoON
○
IO_25 *ST1 Auto ON
○
IO_52 *OUT1 Assign
IO_55 *OUT3 Assign
○
IO_26 *ST2 Auto ON
○
IO_27 *RS1 Auto ON
○
IO_28 *RS2 Auto ON
○
IO_55 *Out1 Pol
IO_57 *Out3 Pol
○
IO_29 *OUT1 assignment
IO_32 *OUT4 assignment
○
IO_33 *OUT1 polarity
IO_36 *OUT4 polarity
○
ML-2
*3
Parameter *2
ML_01 SoftLimit
ML_02 SoftLimChk
ML_03 Org Range (CMD_PLS)
ML_04 P-SoftLimit (CMD_PLS)
ML_05 N-SoftLimit (CMD_PLS)
ML_06 AbsEncOffset (CMD_PLS)
ML_07 1stAccRate 1 (x10kC_P/s2)
ML_08 2ndAccRate 1 (x10kC_P/s2)
ML_09 AcRateSWSpd1 (x100C_P/s)
*2 ◎ : Always displayed.
○ : Displayed when display level is set to "All" or "Basic and extend".
(without a mark): Displayed when display level is set to "All".
*3 Displayed only for the MECHATROLINK-II type servo amplifier.
Main menu Submenu MECHATROLINK-II type Pulse/analog input type