4-134 Options Service Manual
4024-XXX
HCF separation gear group removal
1. Remove the HCF media tray assembly from the printer. See “HCF media tray assembly removal” on
page 4-127.
2. Remove the HCF media feed unit assembly. See “HCF media feed unit assembly removal” on
page 4-132.
3. Remove the HCF feed lift motor. See “HCF feed lift motor removal” on page 4-132.
4. Remove the HCF lift feed gear bracket. See “HCF feed lift gear bracket removal” on page 4-133.
5. Remove the shaft (A) from the HCF lift feed gear bracket (B).
Note: Bearing (C) may become detached.
6. Remove the e-clip with a prying tool securing the separation gear -19 tooth (D) to shaft (A).
7. Remove the separation gear - 19 tooth (D).
8. Remove the bushing (E).
9. Remove the separation gear - 25 tooth (F).
E-ring
A
B
C
D
E
F