4-144 Options Service Manual
4024-XXX
HCF separation roll shaft assembly removal
1. Remove the HCF media tray assembly. See “HCF media tray assembly removal” on page 4-127.
2. Remove the HCF media feed unit assembly. See “HCF media feed unit assembly removal” on
page 4-132.
3. Remove the HCF feed lift motor. See “HCF feed lift motor removal” on page 4-132.
4. Remove the HCF feed lift gear bracket. See “HCF feed lift gear bracket removal” on page 4-133.
5. Remove the HCF separation roll assembly. See “HCF separation roll assembly removal” on
page 4-145.
6. Remove the four screws securing the separation roll shaft assembly (A) to the media feed unit assembly
(B).
7. Remove the separation roll shaft assembly (A).
Note: The HCF media feed unit assembly (B) becomes detached from the separation roll shaft assembly
(A) at the hinge point.
Note: Before re-installing the separation roll shaft assembly (A), ensure the HCF media feed unit assembly (B)
is re-attached at the two hinge points.
B
A