OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-75
Service Engineer Inspection
(For inspection criteria, see
Reference to Check/Replace
Parts.)
Reference to
Check/Replace
Parts
CRG-FFC Connection Error
(CN10)
Check the connection of CARRIAGE
FFC,MW connectors on the
HCB1M and the IPB5.
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
CRG-FFC Connection Error
(CN11)
CRG-FFC Connection Error
(CN12)
RSM-PTG FIFO Connection
Error
- Restart the printer.
- Clean the
non-reflecting tape.
- Check that the non-reflecting tape
on the platen is clean.
- Check that the edge sensor is
clean and correctly installed.
- Check the connection of the edge
sensor connectors.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- Media detect and Line
sensor OKI Data Infotech
- PCB-ASSY-HCB1M
- CARRIAGE FFC,MW
- ROBOT CABLE,MW
- Restart the printer.
- Check the ambient
temperature.
- Check that COOLING FAN,MW is
operating in the ACTUATORS
menu.
- Check the connection of COOLING
FAN,MW connectors.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- COOLING FAN,MW
- PCB-ASSY-HCB1M
- CARRIAGE FFC,MW
- ROBOT CABLE,MW
Head Drive Voltage Error
(No.1)
- Check the connection of HEAD
CABLE,MW connectors on the
HCB1M and the print heads.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- HEAD CABLE,MW
- INKJET HEAD,MW
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
Head Drive Voltage Error
(No.2)
Head Drive Voltage Error
(No.3)
Head Drive Voltage Error
(No.4)
Head Drive Voltage Error
(No.5)
Head Drive Voltage Error
(No.6)
Head Drive Voltage Error
(No.7)
Head Information Error (No.1)
- Check the connection of HEAD
CABLE,MW connectors on the
HCB1M and the print heads.
- Check the connection of
CARRIAGE FFC,MW connectors
on the HCB1M and the IPB5.
- Check the connection of ROBOT
CABLE,MW connectors.
- HEAD CABLE,MW
- INKJET HEAD,MW
- ROBOT CABLE,MW
- CARRIAGE FFC,MW
- PCB-ASSY-HCB1M
- PCB-ASSY-IPB5-100
Head Information Error (No.2)
Head Information Error (No.3)
Head Information Error (No.4)
Head Information Error (No.5)
Head Information Error (No.6)
Head Information Error (No.7)
Head Thermistor Error (No.1)
Head Thermistor Error (No.2)
Head Thermistor Error (No.3)
Head Thermistor Error (No.4)
Head Thermistor Error (No.5)
Head Thermistor Error (No.6)
Head Thermistor Error (No.7)