SP2-XXX (Drum) -1
D0CA/D0C9/D0C8/D0CB 3-42 SM Appendices
3.3 SP2-XXX (DRUM) -1
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
2-005-00
1
Charge DC Voltage: Fix Plain: Bk ENG
*
[0 to 2000 /
590 /
10-V/step]
2-005-00
2
Charge DC Voltage: Fix Plain: C ENG
*
[0 to 2000 /
590 /
10-V/step]
2-005-00
3
Charge DC Voltage: Fix Plain: M ENG
*
[0 to 2000 /
590 /
10-V/step]
2-005-00
4
Charge DC Voltage: Fix Plain: Y ENG
*
[0 to 2000 /
590 /
10-V/step]
2-013-00
1
Environmental Correction: PCU Environment Div. FC:
Display
ENG
*
[0 to 5 / 0 /
1/step]
2-013-00
2
Environmental Correction: PCU Forced Setting ENG
*
[0 to 5 / 0 /
1/step]
2-016-00
1
Lubricant Apply Operation Temperature
Threshold: Low
ENG
*
[0 to 50 / 15 /
1deg/step]
2-016-00
2
Lubricant Apply Operation Temperature
Threshold: High
ENG
*
[0 to 50 / 30 /
1deg/step]
2-016-00
3
Lubricant Apply Operation Page Setting 1: Low
Speed
ENG
*
[0 to 999 / 10 /
1page/step]
2-016-00
4
Lubricant Apply Operation Page Setting 2: Low
Temp.
ENG
*
[0 to 999 / 20 /
1page/step]
2-016-00
5
Lubricant Apply Operation Page Setting 3: Low
Temp. 2
ENG
*
[0 to 999 / 0 /
1page/step]
2-016-00
6
Lubricant Apply Operation Page Setting 4: High
Temp.
ENG
*
[0 to 999 / 20 /
1page/step]
2-016-00
7
Lubricant Apply Operation Coverage Threshold 1:
Low Speed
ENG
*
[0.00 to
100.00 / 10.00
/ 0.01%/step]
2-016-00
8
Lubricant Apply Operation Coverage Threshold 2:
Low Temp.
ENG
*
[0.00 to 60.00
/ 20.00 /