System Maintenance
D0CA/D0C9/D0C8/D0CB 8-46 SM
MultiTouch Sensitivity Adjustment
Adjusts the MultiTouch sensitivity of the operation panel.
Check the influence of external noise. If the detection level is 3 or higher, adjustment is
necessary.
The sensitivity level can be adjusted between "0" and "10". The default setting is "10". If set to
"0", the MultiTouch function is turned off.
• Sensitivity level: 10 (Default)
• Sensitivity level: 0 (MultiTouch function off.)
If the sensitivity level is set to "0", the MultiTouch function is turned off
and you cannot pinch in or out.
• If the sensitivity level is set between "1" and "9", the distance between the 2 points for
detecting MultiTouch increases as the sensitivity level is decreased. At the default setting
(sensitivity level 10), MultiTouch is detected for a distance of approximately 3 cm between
the 2 points. At sensitivity level 1, MultiTouch is detected for a distance of approximately 4
cm between the 2 points.
Press [Detect level confirmation].