EasyManua.ls Logo

Ricoh IM C400F

Ricoh IM C400F
1647 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Maintenance
D0CA/D0C9/D0C8/D0CB 8-46 SM
MultiTouch Sensitivity Adjustment
Adjusts the MultiTouch sensitivity of the operation panel.
Check the influence of external noise. If the detection level is 3 or higher, adjustment is
necessary.
The sensitivity level can be adjusted between "0" and "10". The default setting is "10". If set to
"0", the MultiTouch function is turned off.
Sensitivity level: 10 (Default)
Sensitivity level: 0 (MultiTouch function off.)
If the sensitivity level is set to "0", the MultiTouch function is turned off
and you cannot pinch in or out.
If the sensitivity level is set between "1" and "9", the distance between the 2 points for
detecting MultiTouch increases as the sensitivity level is decreased. At the default setting
(sensitivity level 10), MultiTouch is detected for a distance of approximately 3 cm between
the 2 points. At sensitivity level 1, MultiTouch is detected for a distance of approximately 4
cm between the 2 points.
Press [Detect level confirmation].