Dehumidification Heater (main unit)
SM 2-113 D0CA/D0C9/D0C8/D0CB
D: Base Set (D1965098)
E: Pin Set (D1965092)
2.18.2 ACCESSORY CHECK FOR IM C400 SERIES
All the accessories required to install the Dehumidification Heater (main unit) are available as
the following parts. Order each part separately.
No. Items Q’ty P/N Remarks
1 Heater cover 1 D0CB2898
2 Heater 1 D0CB2554 (EU/AA/CHN)
D0CB2552 (NA)
3 Clamps 3 11050760
4 Clamp 1 11050723
5 Screws M 3 x 6 2 04543006Q
6 Junction harness 1 D1965265 *1
7 Harness with the isolation cap 1 D5735340
• *1 This harness (P/N: D1965265) is also used as a harness for dehumidification heater
(PFU), and Anti-condensation Heater. If you have already ordered this harness for
these heaters, it is not necessary to order this harness again at this time.
2.18.3 INSTALLATION PROCEDURE FOR IM C300 SERIES
• Do not lift the machine with any optional paper feed units attached
If the machine already has one or more optional paper feed unit(s) attached, be sure to
disconnect the machine and paper feed unit(s), and lift them up separately when
moving/transporting. Otherwise, the handle of the paper feed unit will break due to the
mainframe’s weight, and it can cause an injury.