Firmware Update (Auto Remote Firmware Update)
D0CA/D0C9/D0C8/D0CB 5-30 SM
5.6.3 RELATED SP
SP Number Selection
Def.
Overview
SP5-886-111 0: OFF
1: ON
Sets auto update ON/OFF by ARFU.
SP5-886-112 0: OFF
1: ON
Will not run the update when update prohibited time setting is ON
and the current time is in the range of the time set.
• Start time < End time: Prohibited time is from the start time to
the end time on the same day.
• Start time > End time: Prohibited time is from the start time to
the end time on the next day.
• Start time == End time: Prohibited time setting is disabled.
(Update will not be prohibited.)
SP5-886-113 0 to 23
9
SP5-886-114 0 to 23
17
SP5-886-115 0: OFF
1: ON
Even when the auto update function is disabled, downloading the
package is allowed.
The downloaded package can be used with SFU.
SP5-886-116 Display
only
Displays when the latest package check will run.
SP5-886-117 1 to 24
1
Set time for the next version check after retry.
SP5-886-120 0x00 The update will not run if the corresponding bit for each day
below is set to 1.
• prohibited:bit7
• Monday: bit 6
• Tuesday: bit 5
• Wednesday: bit 4
• Thursday: bit 3
• Friday: bit 2
• Saturday: bit 1
• Sunday: bit 0
This setting is not affected by the prohibited time setting.
e.g.) Prohibited on Mon., Fri., Sat., and Sun. : 0x47 (01000111)
SP7-520-011 to
015
Display
only
History of date and time when the update has started.
The five most recent are recorded, the lowest number being the
most recent.
If the last update failed, this is not recorded.
SP7-520-021 to
025
Display
only
History of date and time when the update has finished.
The five most recent are recorded, the lowest number being the