SP3-XXX (Process)
SM Appendices
3-147 D0CA/D0C9/D0C8/D0CB
SP Mode Tables
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
3-421-04
2
Toner Supply Ability:
Set
Environment Coefficient 2 ENG
*
[0.50 to 2.00 / 1.00 /
0.01/step]
3-421-04
3
Toner Supply Ability:
Set
Environment Coefficient 3 ENG
*
[0.50 to 2.00 / 1.00 /
0.01/step]
3-421-04
4
Toner Supply Ability:
Set
Environment Coefficient 4 ENG
*
[0.50 to 2.00 / 0.96 /
0.01/step]
3-422-00
1
Toner Supply Limits:
Set
Max Supply Rate: Bk ENG
*
[0 to 255 / 100 /
1%/step]
3-422-00
2
Toner Supply Limits:
Set
Max Supply Rate: C ENG
*
[0 to 255 / 100 /
1%/step]
3-422-00
3
Toner Supply Limits:
Set
Max Supply Rate: M ENG
*
[0 to 255 / 100 /
1%/step]
3-422-00
4
Toner Supply Limits:
Set
Max Supply Rate: Y ENG
*
[0 to 255 / 100 /
1%/step]
3-422-01
1
Toner Supply Limits:
Set
Min Supply Time: Bk ENG
*
[0 to 255 / 100 /
1msec/step]
3-422-01
2
Toner Supply Limits:
Set
Min Supply Time: C ENG
*
[0 to 255 / 100 /
1msec/step]
3-422-01
3
Toner Supply Limits:
Set
Min Supply Time: M ENG
*
[0 to 255 / 100 /
1msec/step]
3-422-01
4
Toner Supply Limits:
Set
Min Supply Time: Y ENG
*
[0 to 255 / 100 /
1msec/step]
3-432-00
1
Supply Drive Time:
Setting
Drive Time (Maximum) ENG
*
[0 to 1500 / 800 /
1msec/step]
3-440-00
1
Fixed Supply Mode Fixed Rate: Bk ENG
*
[0 to 100 / 10 /
1%/step]
3-440-00
2
Fixed Supply Mode Fixed Rate: C ENG
*
[0 to 100 / 10 /
1%/step]
3-440-00
3
Fixed Supply Mode Fixed Rate: M ENG
*
[0 to 100 / 10 /
1%/step]
3-440-00
4
Fixed Supply Mode Fixed Rate: Y ENG
*
[0 to 100 / 10 /
1%/step]
3-450-00
1
Toner Supply PID:
Setting
Vt Proportion Coef.: Bk ENG
*
[0 to 2550 / 40 /
1/step]
3-450-00
2
Toner Supply PID:
Setting
Vt Proportion Coef.: C ENG
*
[0 to 2550 / 40 /
1/step]