EasyManua.ls Logo

Ricoh IM C400F - Page 1157

Ricoh IM C400F
1647 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SP3-XXX (Process)
SM Appendices
3-165 D0CA/D0C9/D0C8/D0CB
Appendices
SP Mode Tables
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
3-612-13
3
Dev DC Control:
Display
Set:Upper Vb Current:M ENG
*
[0 to 800 / 560 /
1V/step]
3-612-13
4
Dev DC Control:
Display
Set:Upper Vb Current:Y ENG
*
[0 to 800 / 560 /
1V/step]
3-613-00
1
LD Power Control:
Display
Std Speed: Bk ENG
*
[0 to 200 / 100 /
1%/step]
3-613-00
2
LD Power Control:
Display
Std Speed: C ENG
*
[0 to 200 / 100 /
1%/step]
3-613-00
3
LD Power Control:
Display
Std Speed: M ENG
*
[0 to 200 / 100 /
1%/step]
3-613-00
4
LD Power Control:
Display
Std Speed: Y ENG
*
[0 to 200 / 100 /
1%/step]
3-613-01
1
LD Power Control:
Display
Mid Speed: Bk ENG
*
[0 to 200 / 100 /
1%/step]
3-613-01
2
LD Power Control:
Display
Mid Speed: C ENG
*
[0 to 200 / 100 /
1%/step]
3-613-01
3
LD Power Control:
Display
Mid Speed: M ENG
*
[0 to 200 / 100 /
1%/step]
3-613-01
4
LD Power Control:
Display
Mid Speed: Y ENG
*
[0 to 200 / 100 /
1%/step]
3-613-02
1
LD Power Control:
Display
Low Speed: Bk ENG
*
[0 to 200 / 100 /
1%/step]
3-613-02
2
LD Power Control:
Display
Low Speed: C ENG
*
[0 to 200 / 100 /
1%/step]
3-613-02
3
LD Power Control:
Display
Low Speed: M ENG
*
[0 to 200 / 100 /
1%/step]
3-613-02
4
LD Power Control:
Display
Low Speed: Y ENG
*
[0 to 200 / 100 /
1%/step]
3-613-05
1
LD Power Control:
Display
Std Speed: BW ENG
*
[0 to 200 / 100 /
1%/step]
3-613-06
1
LD Power Control:
Display
Mid Speed: BW ENG
*
[0 to 200 / 100 /
1%/step]
3-613-07
1
LD Power Control:
Display
Low Speed: BW ENG
*
[0 to 200 / 100 /
1%/step]
3-613-08
1
LD Power Control:
Display
Std Speed2: BW ENG
*
[0 to 200 / 100 /
1%/step]

Table of Contents