Error Codes
SM 25 D0CK
Code Meaning Suggested Cause/Action
timeout in V.34 phase 3 equalizer
training.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated TX parameters.
Try increasing the TX level.
Try adjusting the TX cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the RX cable equalizer setting.
Try increasing the TX level.
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
0-82 The line was disconnected due to a
timeout in the V.34 phase 4 control
channel start-up.
0-83 The line was disconnected due to a
timeout in the V.34 control channel
restart sequence.
0-84 The line was disconnected due to
abnormal signaling in V.34 phase 4
control channel start-up.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU
(PCB2).
0-85 The line was disconnected due to
abnormal signaling in V.34 control
channel restart.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU
(PCB2).
0-86 The line was disconnected because
the other terminal requested a data
rate using MPh that was not available
in the currently selected symbol rate.
The other terminal was incompatible.
Ask the other party to contact the manufacturer.
0-87 The control channel started after an
unsuccessful primary channel.
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
This does not result in an error communication.
0-88 The line was disconnected because
PPR was transmitted/received 9
(default) times within the same ECM
frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
2-11 Only one V.21 connection flag was
received
Replace the FCU (PCB2).
2-12 Modem clock irregularity
Replace the FCU (PCB2).
2-13 Modem initialization error
Turn off the machine, then turn it back on.
Update the modem ROM.