Bit Switches – 5
D0CK 96 SM
0 0 1 1 V.27ter, V.29, V.33
0 1 0 0 V.27ter, V.29, V.17/V.33
Other settings - Not used
IP Fax Switch 07 (SP No. 1-111-008)
No. Function Comments
0 TSI information
0: Not added, 1: Added
Adds or does not add TSI information to NSS(S).
1 DCN transmission setting at T1 timeout
0: Not transmitted
1: Transmitted
Transmits or does not transmit DCN at T1 timeout.
2 Not used Do not change this setting.
3 Hang up setting at DIS reception disabled
0: No hang up
1: Hang up after transmitting DCN
Sets whether the machine disconnects after DIS
reception.
4 Number of times for training
0: 1 time, 1: 2 times
Selects the number of times training is done at the
same bit rate.
5 Space CSI transmission setting at no CSI
registration
0: Not transmitted
1: Transmitted
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is all
spaces.
6-7 Not used Do not change these settings.
IP Fax Switch 08 (SP No. 1-111-009)
No. Function Comments
0-1 T1 timer adjustment Adjusts the T1 timer.
The default is "00" (35 seconds).
Bit 1 Bit 0
0 0 35s
0 1 40s
1 0 50s
1 1 60s
2-3 T4 timer adjustment Adjust the T4 timer.
The default is "00" (3 seconds).
Bit 3 Bit 2
0 0 3s
0 1 3.5s
1 0 4s
1 1 5s
4-5 T0 timer adjustment Adjusts the fail-safe timer. This timer sets the interval between "setup"