SC8xx: Overall System
D0CA/D0C9/D0C8/D0CB 6-84 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
1. Replace the Controller Board (PCB24)
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics Error: CPU
[XXXX]: Detailed error code
[060A] Interrupt line 0 mask exception error
[060B] Interrupt line 1 mask exception error
[060C] Interrupt line 2 mask exception error
[060D] Interrupt line 3 mask exception error
[060E] Interrupt line 4 mask exception error
Interrupt does not occur though setting interrupt by timer.
• CPU device error
• ASIC device error
1. Replace the Controller Board (PCB24).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics Error: CPU
[XXXX]: Detailed error code
[0610] CPU Interrupt Timer 2 Set Error
Interrupt does not occur though setting interrupt by CPU interrupt timer.
CPU device error
1. Replace the Controller Board (PCB24).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics Error: CPU
[XXXX]: Detailed error code
[0612] ASIC interrupt error
Interrupt Occurs in an ASIC.
• ASIC device error
• Peripherals device error
1. Replace the Controller Board (PCB24).
2. Replace the connected controller option with a new one.