SC9xx: Others
SM 6-125 D0CA/D0C9/D0C8/D0CB
Troubleshooting
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC990-00 D Software Operation Error
Software attempted an unexpected operation.
Parameter error
Internal parameter error
Insufficient work memory
Operation error caused by abnormalities that are normally undetectable.
1. Cycle the main power OFF/ON.
2. Reinstall the software of the controller and BiCU (PCB1).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC991-00 C Recoverable Software Operation Error
Software attempted an unexpected operation.
SC991 covers recoverable errors as opposed to SC990.
Parameter error
Internal parameter error
Insufficient work memory
Operation error caused by abnormalities that are normally undetectable.
Logging only.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC992-00 D Undefined SC Issued
An SC, that is not controlled by the system, occurred.
An SC for the previous model was used mistakenly, etc.
Basically a software bug.
1. Cycle the main power OFF/ON.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC994-00 C Application Item Error
The numbers of executed application items on the operation panel reach the
maximum limit for the operation panel structure.
Too many executed application items
Logging only