CALCulate Subsystem (CATV, K20) R&S FSL
1300.2519.12 6.434 E-11
CALCulate:ATV:RESult Subsystem (CATV, K20)
The CALCulate:ATV:RESult subsystem displays the measurement results for analog TV
measurements.
Commands of the CALCulate:ATV:RESult Subsystem
CALCulate<1|2>:ATV:RESult:CARRiers?
CALCulate<1|2>:ATV:RESult:CN?
CALCulate<1|2>:ATV:RESult:CSO?
CALCulate<1|2>:ATV:RESult:CTB?
CALCulate<1|2>:ATV:RESult:HUM?
CALCulate<1|2>:ATV:RESult:VMODulation?
CALCulate<1|2>:ATV:RESult:CARRiers?
This command reads the measurement values (power, frequency) of the Carrier Power
measurements.
The numeric suffixes <1|2> are irrelevant.
This command is a query only and thus has no *RST value.
Parameter
VCPabsolute vision carrier power absolute
VCFoffset vision carrier frequency offset
S1PRelative sound carrier 1 power relative
S1IFoffset sound carrier 1 intercarrier frequency offset
S2PRelative sound carrier 2 power relative
S2IFoffset sound carrier 2 intercarrier frequency offset
ALL Results of all measurements above, separated by commas.
If a measurement result is not valid, a comma will be output only.
Example
CONF:ATV:MEAS CARR
Configures the analog TV Carrier Power measurement.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:ATV:RES:CARR? VCF
Reads the result of the vision carrier frequency offset parameter.
or
CALC:ATV:RES:CARR? ALL
Reads all measured values.
Characteristics
RST value:
SCPI: device–specific