CALCulate Subsystem R&S FSL
1300.2519.12 6.54 E-11
CALCulate<1|2>:LIMit<1...8>:UPPer:STATe
This command switches on or off the indicated limit line. The limit check is activated separately
with CALCulate<1|2>:LIMit<1...8>:STATe.
In spectrum analyzer mode, the result of the limit check can be queried with
C
ALCulate<1|2>:LIMit<1...8>:FAIL?.
The numeric suffixes <1|2> are irrelevant for this command.
This command is available from firmware version 1.10.
Parameter
ON | OFF
Example
CALC:LIM4:UPP:STAT ON
Switches on limit line 4 (upper limit).
Characteristics
*RST value: OFF
SCPI: conform
Mode
A, ADEMOD, CDMA, EVDO, NF
CALCulate<1|2>:LIMit<1...8>:UPPer:THReshold
This command defines an absolute threshold value for limit lines with relative y–axis scaling.
The absolute threshold value is used in the limit check as soon as it exceeds the relative limit
value.
The unit must correspond to the unit selected with CALCulate<1|2>:LIMit<1...8>:UNIT
(except dB which is not possible). If no unit is indicated, the unit defined with
CALCulate<1|2>:LIMit<1...8>:UNIT is automatically used (exception: dBm instead of
dB).
The units DEG, RAD, S, HZ, PCT are not available in the spectrum analyzer mode.
The numeric suffixes <1|2> are irrelevant for this command.
This command is available from firmware version 1.10.
Parameter
<numeric_value>
Example
CALC:LIM2:UPP:THR –35DBM
Defines an absolute threshold value for limit line 2.
Characteristics
*RST value: –200 dBm
SCPI: device–specific
Mode
A, ADEMOD, CDMA, EVDO