List of Parameters
Parameters
1-123
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Sets the signal source for the setting command to accept the setting value for the motorized potentiometer. The
value becomes effective for a 0/1 edge of the setting command.
Notice: Refer to: P1044
Description: Sets the signal source for the setpoint value for the MOP. The value becomes effective for a 0/1 edge of the setting
command.
Notice: Refer to: P1043
Description: Displays the motorized potentiometer setpoint before it passed the MOP RFG.
Description: Sets the ramp-up time for the internal MOP ramp-function generator.
The setpoint is changed from zero up to limit defined in P1082 within this time.
Notice: Refer to: P1048, P1082
Description: Sets the ramp-down time for the internal MOP ramp-function generator.
The setpoint is changed from limit defined in P1082 down to zero within this time.
Notice: Refer to: P1047, P1082
Description: Displays output frequency of motor potentiometer setpoint ([Hz]).
p1043[0...2] BI: MOP accept rampgenerator setpoint / MOP acc RFG setpo
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
p1044[0...2] CI: MOP rampgenerator setpoint / MOP RFG setpoint
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
r1045 CO: MOP input frequency of the RFG / MOP RFG input
Access level: 3 P-Group: Setpoints Data type: Floating Point
Unit: [Hz] Data set: -
p1047[0...2] MOP ramp-up time of the RFG / MOP ramp-up time
Access level: 2 P-Group: Setpoints Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.00 [s] 1000.00 [s] 10.00 [s]
p1048[0...2] MOP ramp-down time of the RFG / MOP rampdown time
Access level: 2 P-Group: Setpoints Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.00 [s] 1000.00 [s] 10.00 [s]
r1050 CO: Act. Output freq. of the MOP / MOP outp.freq.
Access level: 2 P-Group: Setpoints Data type: Floating Point
Unit: [Hz] Data set: -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinamics G120 Series and is the answer not in the manual?

Siemens Sinamics G120 Series Specifications

General IconGeneral
SeriesSinamics G120
Protection ClassIP20
Communication InterfacesPROFIBUS, PROFINET, USS, Modbus RTU
Safety IntegratedSTO
Power Supply24 V DC
Ambient Temperature-10 to +50 °C (depending on the specific model)
Power Rating0.37 kW to 250 kW
Storage Temperature Range+70 °C
Relative Humidity5% to 95% (non-condensing)

Related product manuals