Parameters
List of Parameters
1-244
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Sets the signal source for the setpoint of the motorized potentiometer if automatic mode P2241 is selected.
Notice: Refer to: P2241
Description: Sets the signal source for the setting command to accept the setting value for the motorized potentiometer. The
value becomes effective for a 0/1 edge of the setting command.
Notice: Refer to: P2244
Description: Sets the signal source for the setpoint value for the MOP. The value becomes effective for a 0/1 edge of the setting
command.
Notice: Refer to: P2243
Description: Displays the motorized potentiometer setpoint before it passed the PID-MOP RFG.
Description: Sets the ramp-up time for the internal PID-MOP ramp-function generator.
The setpoint is changed from zero up to limit defined in P1082 within this time.
Notice: Refer to: P2248, P1082
p2242[0...2] CI: PID-MOP auto setpoint / PMOP auto setpoint
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
p2243[0...2] BI: PID-MOP accept rampgenerator setpoint / PMOP acc RFG setpo
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
p2244[0...2] CI: PID-MOP rampgenerator setpoint / PMOP RFG setpoint
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
r2245 CO: PID-MOP input frequency of the RFG / PMOP RFG input
Access level: 3 P-Group: Technology Data type: Floating Point
Unit: [%] Data set: -
p2247[0...2] PID-MOP ramp-up time of the RFG / PMOP ramp-up time
Access level: 2 P-Group: Technology Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.00 [s] 1000.00 [s] 10.00 [s]