EasyManua.ls Logo

Siemens Sinamics G120 Series - p8851[0...7] CI: PZD to Fieldbus; PZD to FB; r8858[0...15] Fieldbus diagnostic data display; FB diag data displ; r8859[0...7] Fieldbus identification data display; FB id data display

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-286
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: PZD to Fieldbus.
Index: [0] = Transmitted word 0
[1] = Transmitted word 1
[2] = Transmitted word 2
[3] = Transmitted word 3
[4] = Transmitted word 4
[5] = Transmitted word 5
[6] = Transmitted word 6
[7] = Transmitted word 7
Description: Fieldbus diagnostic data display.
Index: [0] = FB Diag. 0
[1] = FB Diag. 1
[2] = FB Diag. 2
[3] = FB Diag. 3
[4] = FB Diag. 4
[5] = FB Diag. 5
[6] = FB Diag. 6
[7] = FB Diag. 7
[8] = FB Diag. 8
[9] = FB Diag. 9
[10] = FB Diag. 10
[11] = FB Diag. 11
[12] = FB Diag. 12
[13] = FB Diag. 13
[14] = FB Diag. 14
[15] = FB Diag. 15
Description: Fieldbus identification data display.
The different Fieldbus types (r8859[0]) are given below:
0 = No additional Fieldbus option available
1 = PROFIBUS DP
2 = DeviceNet
3 = CAN
4 = AS-i
5 = LON
6 = Modbus
10 = PROFInet IO
11 = ES bus (ET 200pro)
4660 = ES bus (ET 200S)
65535 = not defined
p8851[0...7] CI: PZD to Fieldbus / PZD to FB
CU240S PN Access level: 3 P-Group: Communications Data type: Unsigned32
Quick comm. NO Active: YES Data set: -
Can be changed: T
Min Max Factory setting
- - 52[0]
r8858[0...15] Fieldbus diagnostic data display / FB diag data displ
CU240S PN Access level: 3 P-Group: Communications Data type: Unsigned16
Unit: - Data set: -
r8859[0...7] Fieldbus identification data display / FB id data display
CU240S PN Access level: 3 P-Group: Communications Data type: Unsigned16
Unit: - Data set: -

Table of Contents